The innovative instrument design ensures freedom from daily adjustments and alignment. A specially designed honeycomb optical base plate is the foundation for the entire instrument guaranteeing alignment and stability. The laser(s), enclosed microscope, software-switched optics and a unique aberration-corrected polychromator with CCD detector provide an integrated package compact enough to fit on a laboratory bench.
With superb stability and effortless software controlled optics, the NRS Series Raman systems offer performance second to none, with no time-consuming realignment. Simply insert the sample, focus, and collect the spectrum. The integrated, automated XYZ mapping stage with auto-focusing option allows full PC control. Complete operator safety is maintained by the fully enclosed automated sample chamber door which provides a 120 degree opening to allow full microscope access.
All NRS Series Raman instruments include a color CCD sample viewing system with image capture capability. For additional flexibility, a trinocular microscope attachment can be added for direct binocular viewing. Utilizing the same basic optical system, we’ve designed a family of micro-Raman spectrometers that offer a range of capabilities from simple, single laser, single grating instruments to advanced research grade systems with low wave number measurement, wavelength extension from the deep UV to NIR, and the ability to use or add up to 6 lasers.
For application expansion, an automated multi-grating turret, 2 internally mounted detectors and a maximum of 8 lasers ranging from the UV through the NIR are capable of integration with the instrument system. All optical components are PC controlled for maximum flexibility with minimum user interaction.
System Features
Exceptional wavenumber accuracy with a high-precision rotary-encoder direct drive mechanism
Wide wavenumber range up to 8000 cm-1
Automated XYZ with joystick and mouse/keyboard control
Spectra Manager™ operating system for measurement and confocal imaging
Low wavenumber measurement, close to the Rayleigh scatter(NRS-7600)
Auto-alignment of microscope laser introduction optics and Raman scattering light path
Wavenumber calibration using an internal Ne lamp
Unique Dual Spatial Filter (DSF) providing higher spatial resolution than conventional confocal optics, especially in the Z axis
Patented Spatial Resolution Image (SRI) function for simultaneous observation of sample image, laser spot and aperture image
Options
The Objective revolver can be mounted with a range of objective lenses matched to the measurement range (including dedicated NIR) and with a variety of magnification and working distances from x5 to x100
Up to 8 lasers (9 wavelengths) each with a selected Edge or Notch filter
Trinocular for direct observation
Laser wavelengths from deep UV to 1064nm
Detectors include CCD, EM-CCD and InGaAs
Macro-Raman measurement unit for large liquid and solid samples
Measurement polarization
Observation polarization
Fiber optic probes
Transmission Raman
Macro Raman
Heated and cryo-stages
Gas cells
Use with Surface Enhanced Substrates (SERS)
NRS-7500
Resolution 0.7 cm -1/ 0.3 cm -1 (optional)
Measurement Range 50 to 8000 cm -1